viscosity meter

英 [vɪˈskɒsəti ˈmiːtə(r)] 美 [vɪˈskɑːsəti ˈmiːtər]

网络  斯托默粘度计; 粘度计; 黏度计

化学



双语例句

  1. The blood hemorheological values of the nude mice with transplantable lung cancer cell PG were tested simultaneously by FASCO-300 automatic viscosity meter.
    采用FASCO-300型全自动表观黏度快测仪对两组的全血黏度进行检测。
  2. The variation of the velocity profile at the inlet of turbine rotor blades is studied by the numerical simulation of the two-dimensions flow field inside the annulus pipe when the fluid viscosity or the velocity profile at the inlet of the meter change.
    通过环行通道流场二维数值仿真,研究了叶轮入口处速度剖面随流体粘度、传感器入口速度剖面的变化。
  3. Fasting venous samples were drawn in the morning, blood viscosity was detected with automatic blood viscosity meter; The levels of total cholesterol, fibrinogen and triglyceride in venous blood were detected with the automatic biochemistry analyzer;
    早上空腹抽取静脉血,血黏度检测采用自动血液黏度仪,静脉血胆固醇、纤维蛋白原、三酰甘油水平检测采用全自动生化分析仪分析。
  4. The effect of viscosity change on the performance of turbine meter, the correctness of it, the mechanism of it and the means of reducing it are further analyzed.
    深入分析了粘度变化给涡轮流量传感器特性带来的影响、粘度影响的补偿方法、粘度变化影响传感器特性的机理、降低传感器粘度变化敏感度的措施。
  5. The gelatinization temperature, viscosity, and thermal stability of the milling gelatinized starch were analyzed through NDJ-8S viscosity meter.
    采用数显粘度计(NDJ&8S)对微细化淀粉的糊特性进行了分析,主要分析了微细化后淀粉糊化温度、粘度、热稳定性的变化。
  6. The membrane forming solution viscosities of different PVDF initial concentrations at different temperatures were determined by rotating viscosity meter. Appropriate PVDF concentration and temperature range for forming PVDF hollow fiber membrane were determined.
    采用旋转粘度计测定了不同PVDF浓度的铸膜液在不同温度下的粘度,确定了制备中空纤维膜的PVDF浓度范围和适宜纺丝温度。
  7. It is significant for improving the accuracy and extending application fields to reduce the effect of viscosity change on turbine meter.
    降低粘度变化对涡轮流量计的影响,对提高涡轮流量计测量精度和拓展其应用领域具有重要意义。
  8. The eight indexes of hemorheology, flow volume of vertebral artery on the broken side, inside diameter of vein and average bloodstream velocity were observed with HP-1000 color doppler ultrasonic diagnosis apparatus and LING-100 blood viscosity meter.
    利用HP-1000型彩色多普勒超声诊断仪和LING-100血液比黏度计分别观察其治疗前后血液流变学8项指标、患侧椎动脉血流量、血流管径和平均血流速度的变化。
  9. Indexes of RVA viscosity meter and Brabender viscometer change significantly.
    各小麦粉的RVA粘度仪和Brabender粘度仪各指标发生显著变化。
  10. The intrinsic viscosity of solution is tested through ubbelohde viscosity meter, which shows that low temperature is beneficial to dissolve.
    通过乌氏粘度计测试溶液的特性粘度,结果表明,低温溶解效果较好。